VENUS - FFP1 / V-44+ Mask

FEATURES

  • NIOSH approved N95 respirators
  • Flat Fold "C" Style
  • Superior technology micro fine filter media 
  • Dotted pattern edges
  • Embedded Nose clip 
  • Unique fit adjusters
  • Stapled outside filter media
  • Latex free knitted textile elastic


DESCRIPTION 

  • Description
  • Materials
  • Approvals and Standard
  • How to Use
  • Others

VENUS - FFP1 / V-44+ Mask

  • V-4400 series of respirators includesVenus V4400,V44++,V44+ & DhulRakshak V404 respirators 
  • These filtering face piece respiratorsare of fold flat design having C Style &V Style. 
  • V-4400 series of respirators hassuperior micro fine filter mediatechnology which protects againstrespirable suspended particulatematter. These respirators consist ofmultiple layers viz pre-filter, fine filterand skin comfort layer. 
  • V-4400 series of respirators haveunique fit adjustors which provideoptimum fit & comfort. They also havedotted pattern edges for soft feel. 
  • V-4400 series of respirators has latexfree knitted textile elastic which has along life, is skin friendly and does notdeform in high temperature. 
  • These series of respirators haveheadstrap stapled outside filter mediawhich avoids puncture in filter area andis leakproof. 
  • V-4400 series of respirators havenoseclip which is embedded inside themask and the respirator has no metalexposure or loose parts. 

The following materials are used in theproduction of VENUS - FFP1 / V-44+ Mask respirators. 

The following materials are used in theproduction of V4400, V44++, V44+ & DhulRakshak V404 respirators. 

These products do not contain componentsmade from natural rubber latex. 


Approximate minimum mass of products: 


V44++ - 9.5g 

V-44+ - 9.5gV4400 – 9.5g 

Dhul Rakshak V404 – 12g

Approvals

V4400 respirator has been evaluated in thelaboratory and found to comply with all of therequirements of Title 42, Code of FederalRegulations, Part 84 for NIOSH certification. 

V4400, V44++,V44+ & Dhul Rakshak V404respirators have been produced to comply withthe requirement of the Indian standardInstitute IS14746:1999 under an agreedproduction certification scheme operatedduring manufacture in accordance with theBureau of Indian Standards. 

V4400 respirator has been produced to complywith the requirement of EN149:2001+A1:2009 under an agreed productcertification scheme operated in accordancewith IFA in Germany.  

Standards

Venus V4400 respirator meets the requirementof NIOSH N95, EN 149:2001+A1:2009 & ISI9473. 

V44++,V44+ & Dhul Rakshak V404respirators meets the requirement of IS 9473. 

These respirators should be used to protectthe wearer from solid and non-volatile liquidparticles. 

Particulate filter respirators are classified byfiltering efficiency and maximum total inwardleakage performance & also by inhalationresistance. 

These respirators can be used to protectagainst mechanically generated particulatessuch as those generated from sanding,grinding, drilling, sweeping etc. theserespirators have filters that can help reducebreathing in pathogenic biological airborneparticulates such as influenza virus.  

Fitting Instructions

1.  Failure to follow all instructions andlimitations on the use of this respiratorand / or failure to wear this respiratorduring all times of exposure can reducerespirator effectiveness and result insickness or death. 

2. Before use, wearer must first betrained by the employer for properrespirator use in accordance withapplicable Safety and HealthStandards. Respiratory protectionappliances are to be selecteddepending on the type andconcentration of the hazardoussubstances. 

3. The respirator may only be used if thetype and concentration of the harmfulsubstances are known. In case ofunknown substances or concentrationsor variable conditions, breathingapparatus should be used. 

4. Non-ventilated containers, mines,canals should not be entered with theparticle filtering half masks & also notallowed in explosive atmosphere. 

5. If the respirator becomes damaged orbreathing becomes difficult, leave thecontaminated area, discard and replacethe respirator. Also leave thecontaminated area immediately ifdizziness or other distress occurs. 

6. Never alter or modify this respirator.Safety and Health Standards.Respiratory protection appliances are 

Fit Check

1. Cover the front of the respirator with both hands being careful not to disturb the respirator. 


2. Exhale sharply into the respirator. 


3. If air leaks around the nose, readjust the nose clip to eliminate leakage. Repeat the above fitcheck 


4. If air leaks at the respirator edges, work the straps back along the sides of the head toeliminate leakage. Repeat the above fit check. 


Usage Limitations

These respirators are suitable for use inconcentration of solid and non-volatile liquidparticles upto the following limits  

  • Do not use for protection against Gases, Vapor or in atmospheres containing less than 17% Oxygen. 
  • Do not use with beard or other facial hair that prevent direct contact between the face and the edge of the respirator. 
  • Do not use when concentrations of contaminants are immediately dangerous to life and health, are unknown, or when particulate concentration exceed the maximum use level / or other levels determined by your National Occupational Safety and Health Authorities.

Storage and Transportation

V-4400 series of respirators until use shall bestored in the sealed pack to retain itsproperties. For transport such packs shall besuitably packed in outer cartons to protectfrom climatic hazards and mechanical shocks. 

The shelf life of the product is 60 months fromthe date of manufacture. (If stored be-between–50°C and +50°C & Humidity not over80%).The date of manufacture is mentionedon the pack of the respirator. 

Manufacturer

FOR INQUIRIES

(Please fill-up the Form)